FLIR E96 Advanced Thermal Imaging Camera
Advanced Thermal Imaging for Precision Professionals
The camera features advanced thermal imaging technology that enables professionals to detect hidden heat patterns with outstanding clarity. It is well suited for identifying overheating electrical components, mechanical faults, insulation deficiencies, and other temperature related issues. Accurate thermal analysis helps improve maintenance planning, reduce equipment downtime, and enhance operational reliability.
Built for intensive field applications, the FLIR E96 Advanced Thermal Imaging Camera combines a rugged construction with an ergonomic design for comfortable operation during extended inspections. Its intuitive interface allows users to capture, review, and analyze thermal images efficiently, making complex inspection tasks easier and more productive.
This thermal imaging camera is ideal for electrical inspections, industrial maintenance, mechanical diagnostics, building assessments, HVAC analysis, energy management, facility maintenance, and preventive maintenance programs. Its advanced capabilities help engineers and technicians detect hidden thermal issues while improving workplace safety and equipment performance.
Fast thermal image processing and dependable operation enable professionals to complete inspections with greater efficiency. Early identification of temperature anomalies supports proactive maintenance strategies that minimize unexpected failures and extend the service life of critical equipment. Reliable thermal data also contributes to accurate technical reporting and informed decision making.
The FLIR E96 Advanced Thermal Imaging Camera combines advanced imaging technology, professional durability, and user friendly operation in a premium thermal inspection solution. Its reliable performance and comprehensive capabilities make it an excellent choice for engineers, inspectors, maintenance professionals, and industrial specialists who require precise thermal analysis for critical applications.
Outstanding Thermal Imagery
The 640 × 480 thermal resolution plus FLIR UltraMax® and MSX® image enhancement ensure the E96 produces the most virbrant, easiest-to-interpret images in its class.
Intelligent AutoCal™ Optics
Interchangeable, auto-calibrating lenses—from telephoto to wide-angle—allow users to target electrical hot spots safely, check for mechanical faults, and survey roofs or building envelopes quickly.
Streamlined Reporting
Onboard integration with FLIR routing software*, automatic image upload directly to the FLIR Ignite cloud library, a built-in mic for voice annotation, and report generation features all help the E96 streamline your workday. (*Optional accessory software)
IR Resolution
640 × 480 pixels
Thermal Sensitivity/NETD
<40 mK, 24° at 30°C (86°F)
<50 mK, 14° at 30°C (86°F)
Accuracy
±2°C (±3.6°F) or ±2% of the reading
Field of view (FOV)
24° × 18°, 14° × 10°
Digital Camera
5 MP, with built-in LED photo/video lamp
Display
4", 640 × 480 pixel touchscreen LCD with auto-rotation
Storage Media
Removable SD card
Imaging & Optical
Color Palettes
Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava
Detector Type and Pitch
Uncooled microbolometer, 12 µm
Digital Camera
5 MP, with built-in LED photo/video lamp
Digital Zoom
1-8× continuous
Field of view (FOV)
24° × 18°, 14° × 10°
f-number
24°: 1.3
14°: 1.3
Focal Length
24°: 17 mm (0.67 in)
14°: 29 mm (1.41 in)
Focus
Continuous LDM, One-shot LDM, One-shot contrast, Manual
Image Frequency
30 Hz
IR Resolution
640 × 480 pixels
Lens Identification
Automatic
Minimum Focus Distance
24°: 0.18 m (0.59 ft), 14°: 1.0 m (3.28 ft)
Minimum Focus Distance with MSX
24°: 0.5 m (1.64 ft)
14°: 1.0 m (3.28 ft)
Non-radiometric IR video streaming
H.264 or MPEG-4 over Wi-Fi MJPEG over UVC or Wi-Fi
Picture-in-Picture
Resizable and movable
Radiometric IR video recording
Real-time radiometric recording (.csq)
Radiometric IR video streaming
Yes, over UVC
Spatial resolution (IFOV)
24°: 0.67 mrad/pixel
14°: 0.38 mrad/pixel
Spectral Range
7.5-14 µm
Thermal Sensitivity/NETD
<40 mK, 24° at 30°C (86°F)
<50 mK, 14° at 30°C (86°F)
UltraMax
Yes
Viewfinder
No
Measurement & Analysis
Accuracy
±2°C (±3.6°F) or ±2% of the reading
Measurement Presets
No measurement, center spot, hot spot, cold spot, User Preset 1, User Preset 2
Object Temperature Range
-20 to 120°C (-4 to 248°F); 0 to 650°C (32 to 1202°F); 300 to 1500°C (572 to 2732°F)
Spot Meter
3 ea. in live mode
User Interface
Display
4", 640 × 480 pixel touchscreen LCD with auto-rotation
Text
Predefined list or touchscreen keyboard
Voice
60 sec. recording added to still images or video via built-in mic (has speaker) or via Bluetooth®
Power
Battery operating time
>2.5 hours at 25°C (68°F) and typical use
Battery type
Rechargeable Li-ion battery
Environmental & Certifications
Operating Temperature Range
-15 to 50°C (5 to 122°F)
Safety
EN/UL/CSA/PSE 60950-1
Storage Temperature Range
-40 to 70°C (-40 to 158°F)
General
FLIR Inspection Route
Enabled in camera
Form Factor
Pistol
Laser Pointer
Yes
Packaging
Infrared camera with lens, s2 batteries, battery charger, hard transport case, lanyards, front lens cap, power supplies, printed documentation, SD card (8 GB), cables (USB 2.0 A to USB Type-C, USB Type-C to HDMI, USB Type-C to USB Type-C), License card: FLIR Thermal Studio Starter
No items listed for this product.
No resources available for this product.
No reviews yet. Be the first to review this product!