Fluke 435-II Power Quality and Energy Analyzers
Advanced Power Quality and Energy Monitoring Excellence
Fluke 435-II Power Quality and Energy Analyzer is an advanced electrical testing instrument, and the Fluke 435-II Power Quality and Energy Analyzers Price in Bangladesh is an important consideration for professionals seeking reliable solutions for power monitoring and system evaluation. Designed for detailed analysis of electrical performance, this analyzer helps engineers identify power quality issues, evaluate energy usage, and improve the efficiency of electrical systems. It is suitable for industrial facilities, commercial buildings, and professional maintenance applications where accurate measurements are essential.
The Fluke 435-II Power Quality and Energy Analyzer provides comprehensive tools for analyzing electrical system performance. It helps users monitor important power parameters, detect disturbances, and collect detailed information about power conditions. These capabilities allow technicians and engineers to understand system behavior and take effective steps to improve electrical reliability.
With advanced monitoring functions, this analyzer supports troubleshooting activities, preventive maintenance programs, and energy management strategies. It is designed to deliver dependable results for complex electrical environments.
Energy efficiency is a major concern for modern industries and commercial facilities. The Fluke 435-II Power Quality and Energy Analyzer helps users analyze energy consumption patterns and identify opportunities for improving system performance.
By providing detailed energy-related information, the analyzer supports better decision-making and helps organizations develop effective energy management plans. It enables professionals to evaluate electrical efficiency and maintain optimized operations.
The Fluke 435-II Power Quality and Energy Analyzer includes advanced features designed to simplify electrical analysis. It helps measure power quality conditions, record important events, and provide valuable data for system evaluation.
Its professional functionality supports accurate troubleshooting and allows users to identify issues that may affect equipment performance. The analyzer is designed to help maintenance teams improve reliability, reduce operational challenges, and protect sensitive electrical equipment.
The Fluke 435-II Power Quality and Energy Analyzer is widely used in industries where electrical stability and energy performance are important. Common applications include manufacturing plants, automation systems, power distribution facilities, commercial buildings, hospitals, and industrial maintenance projects.
In Bangladesh, organizations with complex electrical systems can benefit from professional power quality and energy analysis. This analyzer helps engineers monitor system conditions, investigate electrical problems, and maintain efficient operations.
Reliable power analysis helps businesses reduce downtime, improve energy efficiency, and maintain consistent electrical performance. The Fluke 435-II Power Quality and Energy Analyzer provides accurate data that supports preventive maintenance and informed decision-making.
By identifying power quality problems and analyzing energy usage, users can improve equipment protection and develop better maintenance strategies. These benefits make it a valuable tool for professionals managing advanced electrical systems.
The Fluke 435-II Power Quality and Energy Analyzer is designed to provide professional performance with practical usability. Its efficient operation allows technicians to perform electrical assessments and analyze results with greater convenience.
The analyzer is built for demanding environments where durability and accuracy are required. Its reliable construction and advanced measurement capabilities make it suitable for regular field applications and industrial testing tasks.
When considering the Fluke 435-II Power Quality and Energy Analyzers Price in Bangladesh, users should evaluate their technical requirements, application needs, product authenticity, and available support services. Choosing the appropriate analyzer ensures accurate measurements and long-term value.
A trusted supplier can provide technical guidance, product information, and after-sales assistance to help customers select the right power quality and energy analysis solution for their requirements.
Fluke is recognized globally for producing reliable electrical measurement instruments for professional users. The Fluke 435-II Power Quality and Energy Analyzer is designed to deliver accurate performance, durable operation, and dependable results in challenging electrical environments.
For organizations focused on improving electrical reliability and energy management, this analyzer provides an effective solution for monitoring, troubleshooting, and optimizing power systems. Its combination of advanced features and professional design makes it a valuable instrument for electrical specialists.
Analyze power quality issues, calculate the costs of wasted energy and prevent downtime with the Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer.
| Volt | ||||
| Model | Measurement Range | Resolution | Accuracy | |
| Vrms (AC + DC) | 434-II | 1 V to 1000 V phase to neutral | 0.1 V | ±0.1% of nominal voltage1 |
| 435-II | 1 V to 1000 V phase to neutral | 0.01 V | ±0.1% of nominal voltage1 | |
| Vpk | 1 Vpk to 1400 Vpk | 1 V | 5% of nominal voltage | |
| Voltage Crest Factor (CF) | 1.0 > 2.8 | 0.01 | ±5% | |
| Vrms½ | 434-II | 1 V to 1000 V phase to neutral | 0.1 V | ± 1 % of nominal voltage |
| 434-II and 435-II | 0.1 V | ±0.2% of nominal voltage | ||
| Vfund | 434-II | 1 V to 1000 V phase to neutral | 0.1 V | ± 0.5 % of nominal voltage |
| 435-II | 0.1 V | ± 0.1 % of nominal voltage | ||
| Amps (accuracy excluding clamp accuracy) | ||||
| Amps (AC + DC) | i430-Flex 1x | 5 A to 6000 A | 1 A | ±0.5% ±5 counts |
| i430-Flex 10x | 0.5 A to 600 A | 0.1 A | ±0.5% ±5 counts | |
| 1mV/A 1x | 5 A to 2000 A | 1A | ±0.5% ±5 counts | |
| 1mV/A 10x | 0.5 A A to 200 A (AC only) | 0.1 A | ±0.5% ±5 counts | |
| Apk | i430-Flex | 8400 Apk | 1 Arms | ±5% |
| 1mV/A | 5500 Apk | 1 Arms | ±5% | |
| A Crest Factor (CF) | 1 to 10 | 0.01 | ±5% | |
| Amps½ | i430-Flex 1x | 5 A to 6000 A | 1 A | ±1% ±10 counts |
| i430-Flex 10x | 0.5 A to 600 A | 0.1 A | ±1% ±10 counts | |
| 1mV/A 1x | 5 A to 2000 A | 1 A | ±1% ±10 counts | |
| 1mV/A 10x | 0.5 A A to 200 A (AC only) | 0.1 A | ±1% ±10 counts | |
| Afund | i430-Flex 1x | 5 A to 6000 A | 1 A | ±0.5% ±5 counts |
| i430-Flex 10x | 0.5 A to 600 A | 0.1 A | ±0.5% ±5 counts | |
| 1mV/A 1x | 5 A to 2000 A | 1 A | ±0.5% ±5 counts | |
| 1mV/A 10x | 0.5 A A to 200 A (AC only) | 0.1 A | ±0.5% ±5 counts | |
| Hz | ||||
| Hz | Fluke 434 @ 50 Hz Nominal | 42.50 Hz to 57.50 Hz | 0.01 Hz | ±0.01 Hz |
| Fluke 434 @ 60 Hz Nominal | 51.00 Hz to 69.00 Hz | 0.01 Hz | ±0.01 Hz | |
| Fluke 435 @ 50 Hz Nominal | 42.500 Hz to 57.500 Hz | 0.001 Hz | ±0.01 Hz | |
| Fluke 435 @ 60 Hz Nominal | 51.00 Hz to 69.00 Hz | 0.001 Hz | ±0.01 Hz | |
| Power | ||||
| Watts (VA, var) | i430-Flex | max 6000 MW | 0.1 W to 1 MW | ±1% ±10 counts |
| 1 mV/A | max 2000 MW | 0.1 W to 1 MW | ±1% ±10 counts | |
| Power Factor (Cos j/DPF) | 0 to 1 | 0.001 | ±0.1% @ nominal load conditions | |
| Energy | ||||
| kWh (kVAh, kvarh) | i430-Flex 10x | Depends on clamp scaling and V nominal | ±1% ±10 counts | |
| Energy Loss | i430-Flex 10x | Depends on clamp scaling and V nominal | ±1% ±10 counts Excluding line resistance accuracy | |
| Harmonics | ||||
| Harmonic Order (n) | DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7 | |||
| Inter-Harmonic Order (n) | OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7 | |||
| Volts % | f | 0.0% to 100% | 0.1% | ±0.1% ±n x 0.1% |
| r | 0.0% to 100% | 0.1% | ±0.1% ±n x 0.4% | |
| Absolute | 0.0 to 1000 V | 0.1 V | ±5%1 | |
| THD | 0.0% to 100% | 0.1% | ±2.5% | |
| Amps % | f | 0.0% to 100% | 0.1% | ±0.1% ±n x 0.1% |
| r | 0.0% to 100% | 0.1% | ±0.1% ±n x 0.4% | |
| Absolute | 0.0 to 600 A | 0.1 A | ±5% ±5 counts | |
| THD | 0.0% to 100% | 0.1% | ±2.5% | |
| Watts % | f or r | 0.0% to 100% | 0.1% | ±n x 2% |
| Absolute | Depends on clamp scaling and V nominal | — | ±5% ±n x 2% ±10 counts | |
| THD | 0.0% to 100% | 0.1% | ±5% | |
| Phase Angle | -360° to +0° | 1° | ±n x 1° | |
| Flicker | ||||
| Plt, Pst, Pst (1 min) Pinst | 0.00 to 20.00 | 0.01 | ±5% | |
| Unbalance | ||||
| Volts % | 0.0% to 20.0% | 0.1% | ±0.1% | |
| Amps % | 0.0% to 20.0% | 0.1% | ±1% | |
| Mains Signaling | ||||
| Threshold Levels | Threshold, limits and signaling duration is programable for two signaling frequencies | — | — | |
| Signaling Frequency | 60 Hz to 3000 Hz | 0.1 Hz | ||
| Relative V % | 0% to 100% | 0.10% | ±0.4% | |
| Absolute V3s (3 second avg.) | 0.0 V to 1000 V | 0.1 V | ±5% of nominal voltage | |
| General Specifications | ||||
| Case | Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2 | |||
| Display | Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated | |||
| Memory | 8GB SD card (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size). | |||
| Real-Time Clock | Time and date stamp for Trend mode, Transient display, System Monitor and event capture | |||
| Environmental | ||||
| Operating Temperature | 0°C ~ +40°C; +40°C ~ +50°C excl. battery | |||
| Storage Temperature | -20°C ~ +60°C | |||
| Humidity | +10°C ~ +30°C: 95% RH non-condensing +30°C ~ +40°C: 75% RH non-condensing +40°C ~ +50°C: 45% RH non-condensing |
|||
| Maximum Operating Altitude | Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V Maximum storage altitude 12 km (40,000 ft) |
|||
| Electro-Magnetic-Compatibility (EMC) | EN 61326 (2005-12) for emission and immunity | |||
| Interfaces | Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery | |||
| Warranty | Three years (parts and labor) on main instrument, one year on accessories | |||
| Full family specifications » | ||||
| 1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if < 1% of nominal voltage 2. 50Hz/60Hz nominal frequency according to IEC 61000-4-30 3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode 4. For nominal voltage 50 V to 500 V |
||||
No resources available for this product.