Fluke MDA-510 and MDA-550 Motor Drive Analyzers
Simplify motor drive diagnostics with trusted precision
Fluke MDA-510 and MDA-550 are professional motor drive analyzers designed to simplify drive system diagnostics and improve maintenance efficiency, making Fluke MDA-510 and MDA-550 Motor Drive Analyzers Price in Bangladesh a popular search among engineers, industrial technicians, and maintenance professionals seeking reliable motor drive testing solutions. These analyzers help evaluate motor drive performance, identify electrical issues, and support efficient troubleshooting for industrial automation and power systems.
The Fluke MDA-510 and MDA-550 provide comprehensive diagnostic capabilities for motor drive systems, allowing users to evaluate electrical performance with confidence. They help identify issues related to voltage, current, drive output, and motor operation, enabling maintenance teams to detect problems early and improve equipment reliability. Accurate diagnostics contribute to better system performance and reduced operational interruptions.
Designed for professional field use, these motor drive analyzers feature an intuitive interface that simplifies complex testing procedures. Clear on-screen guidance and organized measurement functions help technicians perform inspections efficiently without unnecessary complications. The practical design improves productivity while making advanced motor drive analysis more accessible.
The Fluke MDA-510 and MDA-550 motor drive analyzers are widely used in manufacturing facilities, processing plants, automation systems, utility services, commercial industries, and maintenance departments. They support professionals in monitoring motor drive performance, diagnosing electrical faults, and maintaining reliable operation of critical equipment. Their versatility makes them valuable tools for a wide range of industrial environments.
Built to withstand demanding working conditions, the Fluke MDA-510 and MDA-550 feature rugged construction for dependable long term performance. Their durable design supports frequent field inspections while maintaining consistent measurement accuracy. This reliability makes them suitable for routine maintenance as well as advanced troubleshooting applications.
Using the Fluke MDA-510 and MDA-550 helps maintenance teams identify motor drive issues before they lead to unexpected equipment failures. Accurate analysis supports preventive maintenance strategies, improves equipment lifespan, and reduces unnecessary downtime. These benefits contribute to greater operational efficiency and more reliable industrial processes.
Professionals choose the Fluke MDA-510 and MDA-550 because of their dependable diagnostic capabilities, user friendly operation, durable construction, and reliable measurement performance. Whether used for preventive maintenance, motor drive troubleshooting, or system performance evaluation, these analyzers deliver accurate results that support informed maintenance decisions. Buyers searching for Fluke MDA-510 and MDA-550 Motor Drive Analyzers Price in Bangladesh can evaluate these analyzers based on their functionality, reliability, and long term value.
| Measurement Function | |
|---|---|
| DC voltage (V dc) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 999 counts |
| Accuracy at 4 s to 10 us/div | ±(3 % + 6 counts) |
| AC voltage (V ac) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 999 counts |
| 50 Hz | ±(3 % + 10 counts) - 0.6 % |
| 60 Hz | ±(3 % + 10 counts) - 0.4 % |
| 60 Hz to 20 kHz | ±(4 % + 15 counts) |
| 20 kHz to 1 MHz | ±(6 % + 20 counts) |
| 1 MHz to 25 MHz | ±(10 % + 20 counts) |
| True-rms voltage (V ac+dc) | |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 1 mV |
| Full scale reading | 1100 counts |
| DC to 60 Hz | ±(3 % + 10 counts) |
| 60 Hz to 20 kHz | ±(4 % + 15 counts) |
| 20 kHz to 1 MHz | ±(6 % + 20 counts) |
| 1 MHz to 25 MHz | ±(10 % + 20 counts) |
| PWM voltage (V pwm) | |
| Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs |
| Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency |
| Accuracy | As Vac+dc for sinewave signals |
| Peak voltage (V peak) | |
| Modes | Max peak, min peak, or pk-to-pk |
| Maximum voltage with 10:1 or 100:1 probe | 1000 V |
| Maximum resolution with 10:1 or 100:1 probe | 10 mV |
| Accuracy | |
| Max peak, min peak | ±0.2 division |
| Pk-to-pk | ±0.4 division |
| Full scale reading | 800 counts |
| General Specification | |
|---|---|
| Current (AMP) with current clamp | |
| Ranges | Same as V ac, Vac+dc or V peak |
| Scale Factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Accuracy | Same as Vac, Vac+dc or V peak (add current clamp accuracy) |
| Frequency (Hz) | |
| Range | 1.000 Hz to 500 MHz |
| Full scale reading | 999 counts |
| Accuracy | ±(0.5 % + 2 counts) |
| Voltage/Herz ratio (V/Hz) | |
| Purpose | To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives |
| Accuracy | % Vrms + % Hz |
| Voltage unbalance drive input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages |
| Accuracy | Indicative percentage based on Vac+dc values |
| Voltage unbalance drive output and motor input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages |
| Accuracy | Indicative percentage based on V PWM values |
| Current unbalance drive input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy | Indicative percentage based on Aac+dc values |
| Current unbalance drive output and motor input | |
| Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy | Indicative percentage based on A ac values |
| Rise and fall time | |
| Readings | Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot |
| Accuracy | As oscilloscope accuracy |
| Harmonics and spectrum | |
| Harmonics | DC to 51st |
| Spectrum ranges | 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) |
| Shaft voltage | |
| Events / second | Indicative percentage based on rise and fall time (Impulse discharges) measurements |
| Report data capture | |
| Number of screens | Typical 50 screens can be saved in reports (depends on compression ratio) |
| Transfer to PC | Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool |
| Probe settings | |
| Voltage probe | 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 |
| Current clamp | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Shaft voltage probe | 1:1, 10:1, 100:1 |
No resources available for this product.
No reviews yet. Be the first to review this product!